D5: torque control, D6: field weakening and field forcing – Yaskawa CIMR-AU 200V Drives User Manual

Page 284

background image

No.

(Addr.

Hex)

Name

LCD Display

Description

Values

Page

d4-10

(02B6)

Up/Down Frequency

Reference Limit

Selection

Up/Dn LowLim Sel

0: D2-02 or Analog

1: D2-02 Only

0: The lower limit is determined by d2-02 or an analog input.

1: The lower limit is determined by d2-02.

Default: 0

Range: 0, 1

u

d5: Torque Control

No.

(Addr.

Hex)

Name

LCD Display

Description

Values

Page

d5-01

(029A)

Torque Control

Selection

Torq Control Sel

0: Speed Control

1: Torque Control

0: Speed Control

1: Torque Control

Set to 0 when using a digital input to switch between Speed and

Torque Control (H1-oo = 71).

Default: 0

Range: 0, 1

d5-02

(029B)

Torque Reference Delay

Time

Tq Ref Dly Time

Sets a delay time for the torque reference signal. Used to

suppress effects by noisy or fluctuating torque reference

signals.

Default: 0 ms

Min.: 0

Max.: 1000

d5-03

(029C) Speed Limit Selection

Speed Limit Sel

1: Fref Limit

2: Speed Limit Sel

1: Limit set by the frequency reference in b1-01.

2: Limit set by d5-04.

Default: 1

Range: 1, 2

d5-04

(029D) Speed Limit

Speed Limit Val

Sets the speed limit during Torque Control as a percentage of

the maximum output frequency. Enabled when d5-03 = 2. A

negative setting sets a limit in the opposite direction of the Run

command.

Default: 0%

Min.: -120

Max.: 120

d5-05

(029E) Speed Limit Bias

Speed Limit Bias

Sets the speed limit bias as a percentage of the maximum output

frequency.

The bias is applied to the specified speed limit and can adjust

the margin for the speed limit.

Default: 10%

Min.: 0

Max.: 120

d5-06

(029F)

Speed/Torque Control

Switchover Time

Spd/Trq Sw Timer

Sets the delay time for switching between Speed and Torque

Control using an input terminal (H1-oo = 71). Reference

values are held during this switch delay time.

Default: 0 ms

Min.: 0

Max.: 1000

d5-08

(02B5)

Unidirectional Speed

Limit Bias

UnidirSpdLimBias

0: Disabled

1: Enabled

0: Disabled

1: Enabled

Default: 1

Range: 0, 1

u

d6: Field Weakening and Field Forcing

No.

(Addr

Hex.)

Name

LCD Display

Description

Values

Page

d6-01

(02A0) Field Weakening Level Field-Weak Lvl

Sets the drive output voltage for the Field Weakening function

as a percentage of the maximum output voltage.

Enabled when a multi-function input is set for Field Weakening

(H1-oo = 63).

Default: 80%

Min.: 0

Max.: 100

d6-02

(02A1)

Field Weakening

Frequency Limit

Fiel-Weak Freq

Sets the lower limit of the frequency range where Field

Weakening control is valid.

The Field Weakening command is valid only at frequencies

above this setting and only when the output frequency matches

the frequency reference (speed agree).

Default: 0.0 Hz

Min.: 0.0

Max.: 400.0

d6-03

(02A2) Field Forcing Selection

Field Force Sel

0: Disabled

1: Enabled

0: Disabled

1: Enabled

Default: 0

Range: 0, 1

d6-06

(02A5) Field Forcing Limit

FieldForce Limit

Sets the upper limit of the excitation current command during

magnetic field forcing. A setting of 100% is equal to motor no-

load current. Disabled only during DC Injection Braking.

Default: 400%

Min.: 100

Max.: 400

B.4 d: References

284

YASKAWA ELECTRIC TOEP C710616 41E YASKAWA AC Drive - A1000 Quick Start Guide