Auto-tuning operation example, Selecting the type of auto-tuning, Enter data from the motor nameplate – Yaskawa CIMR-AU 200V Drives User Manual
Page 191: 7 auto-tuning, Press or until the auto-tuning display appears, Press to begin setting parameters, Press to display the value for t1-01, Save the setting by pressing, Press to view the default setting, Press

u
Auto-Tuning Operation Example
The following example demonstrates Rotational Auto-Tuning when using OLV (A1-02 = 2) and CLV (A1-02 = 3).
n
Selecting the Type of Auto-Tuning
Step
Display/Result
1. Turn on the power to the drive. The initial display appears.
- MODE -
U1-01= 0.00Hz
U1-02= 0.00Hz
U1-03= 0.00A
DRV
FREF (OPR)
Rdy
JOG
FWD
FWD/REV
LSEQ
LREF
2. Press
or
until the Auto-Tuning display appears.
HELP
- MODE -
PRG
Auto-Tuning
DATA
AUTO
FWD
3. Press
to begin setting parameters.
- A.TUNE -
T1-
01
= 0
*0*
Standard Tuning
PRG
Tuning Mode Sel
Rdy
ESC
FWD
DATA
4. Press
to display the value for T1-01.
<1>
- A.TUNE -
T1-01=
0
*0*
Standard Tuning
PRG
Tuning Mode Sel
Rdy
FWD
“0”
5. Save the setting by pressing
.
Entry Accepted
6. The display automatically returns to the display shown in Step 3.
- A.TUNE -
T1-
01
= 0
*0*
Standard Tuning
PRG
Tuning Mode Sel
Rdy
ESC
FWD
DATA
<1> T1-00 will appear on the display when one of the multi-function inputs has been set to switch between motor 1 and motor 2 (H1-oo = 16).
n
Enter Data from the Motor Nameplate
After selecting the type of Auto-Tuning, enter the data required from the motor nameplate.
Note:
These instructions continue from Step 6 in “Selecting the Type of Auto-Tuning”.
Step
Display/Result
1. Press
to access the motor output power parameter T1-02.
- A.TUNE -
T1-
02
= 0.75kW
(0.00 ~ 650.00)
PRG
Mtr Rated Power
Rdy
ESC
FWD
DATA
“0.75kW”
2. Press
to view the default setting.
- A.TUNE -
T1-02=
0
00.75kW
(0.00 ~ 650.00)
PRG
Mtr Rated Power
Rdy
FWD
“0.75kW”
3. Press
F1
left
,
F2
right
,
,
, and
to enter the motor power nameplate data in
kW.
- A.TUNE -
T1-02= 000.4
0
kW
(0.00 ~ 650.00)
PRG
Mtr Rated Power
Rdy
FWD
“0.75kW”
4. Press
to save the setting.
Entry Accepted
4.7 Auto-Tuning
YASKAWA ELECTRIC TOEP C710616 41E YASKAWA AC Drive - A1000 Quick Start Guide
191
4
Start-Up Programming & Operation