beautypg.com

5 changing the buffer battery, 5 ex c hanging the buf fer bat tery – HEIDENHAIN TNC 410 User Manual

Page 313

background image

15 Tables and Overviews

300

15.5 Changing the Buffer Battery

A buffer battery supplies the TNC with current to prevent the data in
RAM memory from being lost when the TNC is switched off.

If the TNC displays the error message Exchange buffer battery, then
you must replace the batteries. The buffer batteries are located next
to the power supply unit in the logic unit (round, black case). The
TNC also has an power storage device that provide the control with
current while you are exchanging the batteries (for a maximum of
24 hours).

To exchange the buffer battery, first switch off the TNC!

The buffer battery must be exchanged only by trained
service personnel!

Battery type: Three AA-size cells, leak-proof, IEC designation „LR6“

15.5 Ex

c

hanging the Buf

fer Bat

tery

Probe system not ready

Be sure that the transmitting/receiving window of the TS 630 is

oriented to the receiving unit

Check whether the touch probe is ready for operation

Touch probe cannot be retracted

Exchange touch probe battery

Change the battery in the probe head (TS 630).

This message is output when the touch probe reaches the end of a

line.

Time limit exceeded

Enter a time limit that is appropriate for the 3-D surface to be scanned
(CONTOUR LINES cycle).