4 tnc er ro r messag es – HEIDENHAIN TNC 410 User Manual
Page 310
297
HEIDENHAIN TNC 410
15.4
TNC Er
ro
r Messag
es
Wrong RPM
Program a spindle speed within the programmed range.
Chamfer not permitted
A chamfer block must be located between two straight-line blocks with
identical radius compensation.
Faulty program data
The program that was read in through the data interface contains
incorrect block formats.
No editing of running program
A program cannot be edited while it is being transmitted or executed.
Circle end pos. incorrect
■
Enter complete information for connecting arc.
■
Enter end points that lie on the circular path.
Circle center undefined
■
Define a circle center with the CC key.
■
Define a pole with the CC key.
Label number not found
Only call label numbers that have been set.
Scaling factor not permitted
Enter identical scaling factors for coordinate axes in the plane of the
circle.
PGM section cannot be shown
■
Enter a smaller tool radius.
■
4-D movements cannot be graphically simulated.
■
Enter a tool axis for simulation that is the same as the axis in the BLK
FORM.
Radius comp. undefined
Enter radius compensation RR or RL in the first subprogram for
Cycle 14 CONTOUR GEOMETRY.
Rounding-off undefined
Enter tangentially connecting arcs and rounding arcs correctly.
Rounding radius too large
Rounding arcs must fit between contour elements.
Key non-functional
This message always appears when you press a key that is not needed
for the current dialog.
Stylus already in contact
Before probing, pre-position the stylus where it is not touching the
workpiece surface.