1 gener al user p a ra met ers – HEIDENHAIN TNC 410 User Manual
Page 293
15 Tables and Overviews
280
15.1 Gener
al User P
a
ra
met
ers
3-D touch probes and digitizing
Select signal transmission
MP6010
Touch probe with cable transmission: 0
Touch probe with infrared transmission: 1
Probing feed rate for triggering touch probes
MP6120
80 to 3000 [mm/min]
Maximum traverse to first probe point
MP6130
0.001 to 30 000 [mm]
Safety clearance to probing point during automatic measurement
MP6140
0.001 to 30 000 [mm]
Rapid traverse for triggering touch probes
MP6150
1 to 300 000 [mm/min]
Measure center misalignment of the stylus when calibrating a triggering touch probe
MP6160
No 180° rotation of the 3-D touch probe during calibration: 0
M function for 180° rotation of the 3-D touch probe during
calibration: 1 to 88
Radius measurement with the TT 120 touch probe: Probing direction
MP6505
Positive probing direction in the angle reference axis (0° axis): 0
Positive probing direction in the +90° axis: 1
Negative probing direction in the angle reference axis (0° axis): 2
Negative probing direction in the +90° axis: 3
Probing feed rate for second measurement withTT 120, stylus shape, corrections in TOOL.T
MP6507
Calculate feed rate for second measurement with TT 120,
with constant tolerance: +0
Calculate feed rate for second measurement with TT 120,
with variable tolerance: +1
Constant feed rate for second measurement with TT 120: +2
Maximum permissible measuring error with TT 120 during measurement with rotating tool
Required for calculating the probing feed rate in
connection with MP6570
MP6510
0.002 to 0.999 [mm]
(recommended input value: 0.005 mm)
Feed rate for probing a stationary tool with the TT 120
MP6520
80 to 3000 [mm/min]