beautypg.com

7 a dditional f unctions – HEIDENHAIN TNC 410 User Manual

Page 231

background image

10 Programming: Q Parameters

218

FN19: PLC
Transferring values to the PLC

The function FN19: PLC transfers up to two numerical values or Q
parameter contents to the PLC.

Resolution and units:

1 µm and 0.001° or
0,1 µm and 0.0001°

The resolution depends on the machine parameter 4020
(default setting is 1 µm and 0.001°).

Example: Numerical value 10 (meaning 10 µm or 0,01°) is sent to the
PLC.

56 FN19:PLC=+10/+Q3

1

0.7 A

dditional F

unctions