7 additional functions, 7 a dditional f unctions – HEIDENHAIN TNC 410 User Manual
Page 226
213
HEIDENHAIN TNC 410
Error code and text
1000
Spindle ?
1001
Tool axis is missing
1002
Slot width too large
1003
Tool radius too large
1004
Range exceeded
1005
Start position incorrect
1006
Rotation not permitted
1007
Scaling factor not permitted
1008
Mirroring not permitted
1009
Datum shift not permitted
1010
Feed rate is missing
1011
Entry value incorrect
1012
Wrong sign programmed
1013
Entered angle not permitted
1014
Touch point inaccessible
1015
Too many points
1016
Contradictory entry
1017
CYCL incomplete
1018
Plane wrongly defined
1019
Wrong axis programmed
1020
Incorrect RPM
1021
Radius comp. undefined
1022
Rounding-off undefined
1023
Rounding radius too large
1024
Program start undefined
1025
Excessive nesting
1026
Angle reference missing
1027
No fixed cycle defined
1028
Slot width too large
1029
Pocket too small
1030
Q202 not defined
1031
Q205 not defined
1032
Enter Q218 greater than Q219
1033
CYCL 210 not permitted
1034
CYCL 211 not permitted
1035
Q220 too large
1036
Q222 must be greater than Q223
1037
Q244 must be greater than 0
1038
Q245 must not equal Q246
1039
Angle range must be under 360°
1040
Q223 must be greater than Q222
1041
Q214: 0 not permitted
10.7 Additional Functions
Press the DIVERSE FUNCTION soft key to call the additional
functions. The TNC then displays the following soft keys:
Function
Soft key
FN14:ERROR
Display error messages
FN15:PRINT
Unformatted output of texts or Q parameter values
FN18:SYS-DATUM READ
Read system data
FN19:PLC
Transfer values to the PLC
FN 14: ERROR
Displaying error messages
With the function FN14: ERROR you can call messages under
program control. The messages were preprogrammed by the
machine tool builder or by HEIDENHAIN. If the TNC encounters a
block with FN 14 during program run, it will interrupt the run and
display an error message. The program must then be restarted. The
error numbers and the associated texts are listed in the table at
right.
Resulting NC block
The TNC is to display the text stored under error number 254:
180 FN14: ERROR = 254
Range of error numbers
Standard dialog text
0 ... 299
FN 14: ERROR CODE 0 .... 299
300 ... 999
No standard dialog text prepared
1000 ... 1099
Internal error messages (see table
at right)
1
0.7 A
dditional F
unctions