7 Programming: Miscellaneous Functions

110

Contour filter: M124

Standard behavior
The TNC includes all available points in its calculation of a contour
transition between contour elements.

Behavior with M124

You can adjust the effect of M124 by redefining machine
parameters.

The TNC filters contour elements with small point spacing and
inserts a transitional contour.

Shape of contour transition

Tangential circle: MP7415.0 = 0
an acceleration jump results from the change in the curvature at
the connection points.

Third-degree polynomial (cubic spline): MP7415.0 = 1
There is no velocity jump at the connection points.

Fifth-degree polynomial: MP7415.0 = 2
There is no acceleration jump at the connection points.

Seventh-degree polynomial: MP7415.0 = 3 (standard setting)
There is no jump in the rate of acceleration change.

Rounding of contour transitions

Do not round the contour transition: MP7415.1 = 0
execute the contour transition as defined in MP7415.0 (standard
contour transition: 7th-degree polynomial)

Round the contour transition: MP7415.1 = 1
Execute the contour transition so that the straight line segments
remaining between the contour transitions are also rounded.

Maximum length T of a contour element
With parameter T you define the length up to which the TNC will
filter out contour elements. If you have defined a permissible
contour deviation in M112 the TNC will respect it. If you do not
enter a maximum contour deviation, the TNC calculates the most
exact contour transition possible without reducing the programmed
feed rate.

7.

4 Miscellaneous F

unctions f

or Cont

our

ing Beha

vior