Controlling Xplay devices using automation protocols
Configuring Xplay to use the Evertz protocol over Serial
Xplay can be configured to support the Evertz protocol as a means of controlling the playout
of graphics content to Vertigo output devices. Thus far, Grass Valley has used Encoda
Automation System running the Evertz protocol (Evertz 9525 DSK-LG) controlling Xplay.
N
OTE
The Evertz protocol is somewhat limited in that there is no real control over layering of
templates on the device. Therefore, in the current implementation there is no guarantee that
a particular template will be loaded onto a particular keyer. If strict layering control is desired
then another protocol, such as Xprotocol, should be considered (see
).
To configure Xplay to use the Evertz protocol over Serial to control a device:
1.
Open Xplay’s D
EVICE
M
ANAGER
and verify that the devices and device keyers that the
Evertz protocol will control are properly configured and assigned (see
connecting Xplay to playout devices” on page 2-8
2.
Verify that Xplay’s A
UTOMATION
settings and the renderer’s automation settings are
appropriate for automation control (see
“Specifying Automation settings in Xplay” on
3.
Open Xplay’s A
UTOMATION
C
ONFIGURATION
window and create an instance of the
Evertz protocol for the device that is to be controlled by automation.
a.
Select T
OOLS
>C
ONFIGURE
A
UTOMATION
.
The X
PLAY
A
UTOMATION
C
ONFIGURATION
).
Figure 5-4. The Xplay Automation Configuration window
b.
In the D
EVICE
TO
PROTOCOL
MAPPINGS
section, click the A
DD
P
ROTOCOL
button next
to the device that you want to map the Evertz protocol to.