Rsmv status, Rsmv status screens, Vcc-x operator interface sd – Orion System VCC-X Controller User Manual
Page 67: 67 rsm #1-#4 status screen index, Status screens - general procedures
VCC-X Operator Interface SD
RSMV STATUS
67
RSM #1-#4 Status Screen Index
The available Status Screens for the RSMV Modules are listed by
sequential screen number. The following is a list of all the RSMV
Status Screens in numerical order with a brief listing of the Status
features available on each screen. The A1 & A2 notations will be B1
& B2 for RSM #2, C1 & C2 for RSM #3, and D1 & D2 for RSM #4.
Screen #1
Compressor A1 & A2
On/Off
&
Current
Position
Screen #2
Coil Temperature, Coil Setpoint,
and
Suction
Pressure
Screen #3
Compressor A1 Coil Temperature,
Compressor
A1
Superheat,
Expansion
Valve
A1
Position
Screen #4
Compressor A2 Coil Temperature,
Compressor
A2
Superheat,
Expansion
Valve
A2
Position
Screen #5
Head Pressure Reading, Head Pressure
Setpoint,
and
Condenser
Signal
Screen #6
Low Suction Pressure Alarm, Unsafe Suction
Pressure
Alarm,
High
Head
Pressure
Alarm
Screen #7
Compressor A1 Trip Alarm, Compressor A2
Trip
Alarm,
No
Head
Pressure
Alarm
Screen #8
No Suction Pressure Alarm,
Communication
Timeout
Alarm,
No
Coil
Temperature
A1
Alarm
Screen #9
No Coil Temperature A2 Alarm, Low
Superheat A1 Alarm, Low Superheat A2 Alarm
Status Screens - General Procedures
From any menu screen, press
. The Unit Selection
Screen, shown below,
will appear requesting that you enter the unit
ID number.
Enter Unit Address
Then Press Enter
Selected Unit #_1
Press Down
Enter
the correct unit ID number of the Controller that the RSMV
Module(s) are connected to and press
. Once communica-
tion is established, the *00* message will go away. Then
press
<
>
.
You will then see the Status Selection Screen(s) below:
VCC-X Status
RSM #1
RSM #2
Select & Press Enter
RSM #3
RSM #4
Select & Press Enter
Use the arrow keys to move the cursor to select which Module’s
Status Screens you wish to view. Then press
. The fi rst
Status Screen will appear. Press
<
>
to scroll through the screens.
NOTE:
If the *00* remains, it indicates a communication
failure to the controller.
Status Screen 1 - Compressor 1 & 2 Enable
and Current Position
RSM #1-4 Status
Compressor 1: ON/OFF
Compressor 2: ON/OFF
Comp Position: 0%
Line 2 Compressor 1 Enabled or Disabled
Current status of the fi rst Compressor.
Line 3 Compressor 2 Enabled or Disabled
Current status of the second Compressor.
Line 4 Current Position
Current position of the Modulating Compressor.
Status Screen 2 - Coil (Saturation) Temp &
Setpoint & Suction Pressure
RSM #1-4 Status
Coil Temp: 0.0ºF
Coil Setpt: 0.0ºF
Suction Pr: XXX PSI
Line 2 Coil (Saturation) Temperature
If a Suction Pressure Transducer has been installed and
confi gured on the unit, the calculated Evaporator Coil
Suction (Saturation) Temperature will appear on this
line. If not, this line will display 0°F.
Line 3 Coil (Saturation) Temperature Setpoint
During DX dehumidifi cation, compressor(s) will be
staged/modulated to maintain this Coil Suction
(Saturation) Temperature Setpoint. If indoor humidity
reset of the Coil Setpoint has been confi gured, this will
be the current calculated setpoint.
Line 4 Suction Pressure
This is the current Suction Pressure.
RSMV Status Screens
- VCB-X Controller VCB-X VCB-X Modular Service Tool VCM Controller Operator Interfaces SD VCM-X/RNE Controller VCC-X Modular System Manager SD Modular System Manager SD Quick Start VCM-X/RNE Controller Operator Interface SD SA E-BUS Controller VAV II Controller v.1 CAV II Controller v.1 MUA II Controller v.1 VAV II Controller v.2 CAV II Controller v.2 MUA II Controller v.2