Zone

Zone

VCC-X CONFIGURATION

VCC-X Operator Interface SD

24

VCC-X Confi guration Screen Index

VCC-X Confi guration Screen Index

The available Confi guration Screens for the VCC-X Controller are
listed on the next few pages by sequential screen number. When each
VCC-X Controller is confi gured for the fi rst time, it is best to start
with screen #1 and proceed to each screen in numerical order until
you have viewed all available Confi guration Screens. This ensures
that you have seen all the available VCC-X Controller confi gura-
tion possibilities and have the opportunity to change or accept the
defaults for each screen.

Once the unit is confi gured and you decide to change one of the
screen options, it is helpful to know what screen number contains the
confi guration you wish to change. With this in mind, the following is
a list of all the VCC-X Confi guration Screens in numerical order with
a brief listing of the confi guration feature available on each screen.

Screen #1

Sensor Scaling (Fahrenheit / Celsius)

Screen #2

RSM 1 & RSM 2 Installed

Screen #3

RSM 3 & RSM 4 Installed

Screen #4

EM1 Expansion Module Installed

Screen #5

MHGRV-X and MODGAS-X Installed

Screen #6

12 Relay E-BUS Expansion Module Installed

Screen #7

Preheat-X Controller Installed

Screen #8

HVAC Mode Enable Source

Screen #9

HVAC Mode Set By Remote Contact

Screen #10

SAT Reset Source

Screen #11

Reset Rate Interval

Screen #12

Space Sensor Type

Screen #13

Remote Space Sensor Board Address

Screen #14

Outdoor Sensor Type

Screen #15

Return Sensor Type

Screen #16

Static Pressure Control

Screen #17

Static/Fan Control Rate

Screen #18

Static Pressure Control Max Adjust

Screen #19

Fan Voltage Output - Min/Max

Screen #20

Supply Fan Cycle Mode

Screen #21

Fan Proving

Screen #22

Fan Starting Delay

Screen #23

Purge Mode Delay

Screen #24

Heat Type

Screen #25

Modulating Heat Output Signal - Min/Max

Screen #26

Cool Type

Screen #27

Mech Heat/Cool Alarm Delay

Screen #28

Economizer Control Type

Screen #29

Title 24 Economizer

Screen #30

Economizer in Unoccupied Mode

Screen #31

Economizer Enable Source

Screen #32

Economizer Control Loop Rate

Screen #33

Economizer Voltage Output - Min/Max

Screen #34

CO

2

Sensor Installed

Screen #35

Building Pressure Sensor Installed

Screen #36

Building Pressure Control

Screen #37

Building Pressure Control Rate

Screen #38

Building Pressure Control Max Adjust

Screen #39

Exhaust Fan Output

Screen #40

Dehumidifi cation Control

Screen #41

Humidity Control Sensor Type

Screen #42

Reheat Control

Screen #43

Type of Airfl ow Station

Screen #44

Monitor Outdoor Air Airfl ow

Screen #45

Control Outdoor Air Airfl ow

Screen #46

Outdoor Airfl ow Duct Size

Screen #47

Monitor Supply Air Airfl ow

Screen #48

Supply Airfl ow Duct Size

Screen #49

Monitor Return Air Airfl ow

Screen #50

Return Airfl ow Duct Size

Screen #51

Monitor Exhaust Airfl ow

Screen #52

Exhaust Airfl ow Duct Size

Screen #53

Morning Warm Up Type

Screen #54

AHU Uses Schedule Number

Screen #55

Daylight Adjustment Start/Stop Date

Screen #56

Trend Log Rate

Screen #57

Emergency Shutdown

Screen #58

Dirty Filter

Screen #59

Broadcast Outdoor Air Temperature

Screen #60

Broadcast Outdoor RH

Screen #61

Broadcast Building Pressure

Screen #62

Broadcast to Boxes

Screen #63

Cool Stage Up and Down Delays

Screen #64

Cool Stage Min Run and Min Off Delays

Screen #65

Heat Stage Up and Down Delays

Screen #66

Heat Stage Min Run and Min Off Delays

Screen #67

Heat/Cool Changeover Delay

Screen #68

Return Air Bypass Control

Screen #69

Morning Cool Down Type

Screens
#70-76

VCC-X Relay 1-8 Confi guration Screens

Screens
#77-81

EM1 Relays 1-5 Confi guration Screens

Screen
#82-93

12 Relay Confi guration Screens