318
Console Revision History
Add power-on caption control to address 23,24,25 in football to column 16 of each for
code 6611
Change auto racing to default to show current lap in manual codes
Change auto racing to display lap in race mode and display lap time in qualify mode
Change test code to fix the problem of manual horn key causing the rotating column
and row to stop
Add output for TI-218 in basketball at address 2
Fix wrestling adv time problem of switching adv indicator when adv time reaches the
main clock period time setting
Modify wrestling scoreboard test to display red and green on LCD instead of home
and guest
Fix wrestling new game problem of not turning off the adv time clock so when the
main clock is started, the adv time starts counting down
Correct the problem of the period end time not being saved on a loss of power and
then resume game
Version 1.4.0
Release Date: 2 February 2001
Fixed the scoreboard test program for auto racing boards to not blank the clock
section
Added a scoreboard test function for MS-2001 when code 02 is entered without a
previous sport code
Added a new code 6402 for football on hockey 2024 boards
Changed auto racing pylon scoreboard outputs for pos 41-45 to use the correct RTD
item numbers and display the correct information
Version 1.4.1
Release Date: 1 March 2001
Add outputs for a new MS-2009 to soccer and to football
Add basketball and hockey codes for use at the American Airlines Center in Dallas
codes 9101 (basketball) and 9401 (hockey)
Add outputs for SO-2008 to soccer (Code 7601) and football (code 6601) and
hockey/lacrosse (code 4601)
Add x100 team score segments to hockey boards with address 71 to basketball codes
1401 and 1402 and to hockey codes 4401 and 4402 for testing purpose
Version 1.4.2
Release Date: 12 April 2001
Added a menu option to baseball to allow a 2 digit time or at bat to be displayed in
the at bat section of the output. This is done for a new model of scoreboard BA-2005
Added a minimum speed selection for radar gun on pitch and speed
Corrected problem with speed of pitch not working with Stalker
®
radar gun when
gun is set for whole digit and no tenths
Added a medical timer so it will count beyond the end of a period
Fixed judo osaekomi timer so it will count beyond the end of a period
Added address 22 for 6 digit time on the TI-2006 to the multi-purpose timer
Added an output for SO-1830, 1930 to code 4601 hockey/lacrosse for use in lacrosse
that will show period on the home penalty digit
Version 1.4.3
Release Date: 8 June 2001
Added a new address 17 for Tuff Sport™ basketball boards to codes for basketball,
volleyball, wrestling, hockey, and football
Added 16 column caption on address 223 for Kemper Arena to codes 1103, 2103,
3103, 4103 and 6103