Creating and Starting a Test Case
Ethernet and Fibre Channel Application
85
Ethernet RFC 2544 Test Case
3f. Press the VLAN tab, select the VLAN
check box when required and set its
parameters to complete the test setup.
For more information on VLAN refer to
MAC on page 222.
3g. Select the Frame Format. Choices are
Ethernet II and 802.3 SNAP. Refer to Frame Format on page 222
for more information.
4. For additional configuration parameters, refer to RFC 2544 Tabs on
5. Press the Start button to start the test. Pressing the Start button while
in test setup window, will automatically switch to the first enabled test
procedure tab (refer to RFC 2544 Tabs on page 251).
At least one of the RFC 2544 test procedures (Throughput,
Back-to-Back, Frame Loss or Latency) has to be enabled to start the
test. Test procedures that are enabled will be performed following this
order: Throughput, Back-to-Back, Frame Loss, and Latency.
6. For additional results, refer to RFC 2544 Tabs on page 251.