EXFO FTB-8500 Series for FTB-200 User Manual
Page 88

Creating and Starting a Test Case
74
FTB-8500 Series and FTB-8120NGE/8130NGE
Ethernet EtherSAM (Y.1564) and RFC 2544 Dual Test Set Test Cases
To create an EtherSAM (Y.1564) or RFC 2544 Dual Test Set test
case, first create the test on the remote module as follow:
1. Test configuration:
1a. Select
Ethernet 10/100/1000
or Ethernet 10G as
the Interface Type.
Interface Type is not
available with
FTB-8510G.
1b. Select Single Port as
the Topology.
Topology is only
available with
FTB-8510B.
1c. Select EtherSAM
(Y.1564) or RFC 2544
as the application type.
1d. Select the Dual Test Set check box to enable the control of a
remote compatible module (FTB-8510B, FTB-8510G,
FTB-8525/FTB-8535, FTB-8120NGE/FTB-8130NGE, or
RTU-310/RTU-310G). For FTB-8510B, Dual Test Set is only
available in Single Port Topology. This setting is not selected by
default.
1e. Select the Remote test Mode.
1f. Type an ID for this remote unit. Up to 16 characters are allowed.
1g. For FTB-8120NGE and FTB-8130NGE, select the latency
measurement mode; Round-Trip or One-Way. For more
information, refer to Latency Measurement on page 303 for
RFC-2544, or Latency Measurement on page 283 for EtherSAM.