System Tabs

Ethernet and Fibre Channel Application

345

Default/Ethernet Test Preferences

Configuration

Laser On: Selects Laser On every time a test is created manually using
the wizard. The Laser On check box is selected by default.

Couple Start/Enable TX: Available with FTB-8510B and FTB-8510G
only. Automatically selects the stream transmission when the test is
started. This setting applies to Frame Analyzer test only. The stream
transmission stops when the test is stopped. The Couple Start/Enable
TX
check box is cleared by default. Refer to Enable TX - On/Off button
on page 206 for more information.

Interface Configuration

Note: The following IPv4 configuration parameters apply to both the stream and

the interface and are available for both ports (FTB-8510B). The
configuration of Stream Tag in TX applies as well to IPv6.

Enable Auto-Negotiation: The Auto-Negotiation check box should
be selected if the connected switch is also set to Auto-Negotiation,
otherwise the Auto-Negotiation check box should be cleared.
When selected, the Ethernet and Fibre Channel Application will
indicate to the switch which parameters to use. The Enable
Auto-Negotiation
check box is selected by default. Available with
10/100/1000Mbps interfaces.

Enable Stream Tag in TX allows to automatically select the
Stream Tag check box (refer to page 206) every time a Frame
Analyzer
test is created. The Enable Stream Tag in TX check box
is selected by default.

IP Address: Enter the IP address for both the stream and the
Ethernet port. The factory IP address is 10.10.x.y, where x and y
are respectively the two least significant bytes of the port default
MAC address.