EXFO FTB-8500 Series for FTB-200 User Manual
Page 285

RFC 2544 Tabs
Ethernet and Fibre Channel Application
271
Frame Loss Results
Frames Count
TX-to-RX/P1-to-P2/P2-to-P1/Local to Remote/Remote to Local: Gives
the number of frames for the indicated direction. P1-to-P2/P2-to-P1 is
only available with FTB-8510B.
TX Frame Count: Indicates the number of transmitted frames.
RX Frame Count: Indicates the number of received frames.
Frame Loss Results
Frame Size: Indicates the frame sizes used for the test. Up to seven
different frame sizes can be displayed.
Note: The “--” indicates that the result is not available because the test has not
run yet or the measured value is not valid.
TX-to-RX/P1-to-P2/P2-to-P1/Local to Remote/Remote to Local:
Gives the number of frames for the corresponding direction.
P1-to-P2/P2-to-P1 is only available with FTB-8510B.
Current Trial: Indicates the current trial number.
Current Step: Indicates the current percentage of the testing rate.
Units: Indicates the throughput result unit which is % Loss.
Displayed Step: Indicates what TX-to-RX/P1-to-P2/P2-to-P1/Local
to Remote/Remote to Local rate result is displayed. This setting is
only available when the test is running or completed.
P1-to-P2/P2-to-P1 is only available with FTB-8510B.
Displayed Results: Select the displayed result mode: Current,
Minimum, Maximum, or Average. The default setting is Current.