Tools Tabs
Ethernet and Fibre Channel Application
367
Ping
Advanced: Press Advanced to access the advanced setup menu. Refer
to Advanced Ping on page 460 for more information.
Configuration
Timeout (ms): Enter the maximum time allowed between an ICMP
echo and response. Choices are 200 ms to 10000 ms. The default
setting is 4000 ms.
Delay (ms): Available for ping only. Enter the delay between each
attempt (PING). Choices are 100 to 10000 ms. The default setting is
1000 ms.
Data Size (Bytes): Available for ping only. Enter the buffer size that will
be sent to the network device to be detected. Choices are 0 to 1472
bytes. Default value is 32 bytes.
Time To Live (TTL) for IPv4
Hop Limit (TTL) for IPv6
Enter the maximum number of hops the packet can go through.
Choices are 1 to 255. The default setting is 128.
Flow Label (IPv6 only): Enter the Flow Label number that will be used
to identify a series of related packets from a source to a destination.
Choices are 0 to 1048575. The default setting is 0.
IPv6
IPv4