beautypg.com

Fc rx, Alarm analysis – EXFO FTB-8500 Series for FTB-200 User Manual

Page 212

background image

Traffic Analyzer Tabs

198

FTB-8500 Series and FTB-8120NGE/8130NGE

FC RX

FC RX

Press Main, Test, Traffic Analyzer, and FC RX.

Alarm Analysis

Link Down: Indicates that the fibre channel connection is down. The
fibre channel connection is down if there is a local or a remote fault
condition including LOS, loss of code-group synchronization, and PSP
failure (when enabled).

Local Fault (FC 10x): Indicates that at least one of the following events
is detected: LOS, Loss of bit synchronization, Loss of Block
synchronization
, Link down, or High BER (High BER is true when the
bit error ratio > 10

-4

on a fixed 125 μs time period).

Remote Fault (FC 10x): Indicates that a Remote Fault event is
detected.

Note: Alarms/Errors are updated only during test execution.