Statistics – EXFO FTB-8500 Series for FTB-200 User Manual
Page 193

Traffic Analyzer Tabs
Ethernet and Fibre Channel Application
179
Flow Control
Statistics
Pause Time: Displays the time during which the port was in waiting
mode.
Total: Indicates the total number of pause time received from the link
partner.
Last: Indicates the last pause time received from the link partner.
Maximum: Indicates the maximum pause time received from the link
partner.
Minimum: Indicates the minimum pause time received from the link
partner.
Unit: Allows the selection of the measurement unit. Choices are
Quanta, μs, ms, and s. The default setting is Quanta.
Pause Frame Count: The number of received valid flow-control
frames. Frames that have a type/length field equal to 8808h will be
counted as a pause frame.
Total: Indicates the total number of received pause frames.
Abort: Indicates the number of received pause frames with a Quanta
equal to zero; cancelling the pause frames.
TX: Indicates the number of transmitted flow control pause frames.
RX: Indicates the number of received flow control frames having a
MAC address equal to 01:80:C2:00:00:01 or equal to the MAC address of
the receiving port.