EXFO FTB-8500 Series for FTB-200 User Manual
Page 85
![background image](/manuals/736440/85/background.png)
Creating and Starting a Test Case
Ethernet and Fibre Channel Application
71
EtherSAM (Y.1564) Test Case
3f. Press the PBB-TE tab and
selectthe PBB-TE Config
check box to enable the
capability to generate and
analyze streams with PBB-TE
data traffic including
configuration of B-MAC
(source and destination),
B-VLAN and I-tag, and to filter received traffic by any of these
fields. PBB-TE is a software option and needs to be enabled to
give access to the PBB-TE testing capability (refer to Software
Options on page 355). PBB-TE is not available when the MPLS
check box is selected. Refer to PBB-TE Interface configuration on
page 439 for more information.
3g. Press the MPLS tab and select the
MPLS check box to enable the
capability to generate and analyze
streams with up to two layers of
MPLS labels and to filter received
traffic by MPLS label or COS. MPLS
is a software option and needs to be enabled to give access to the
MPLS testing capability (refer to Software Options on page 355).
MPLS is not available when the PBB-TE check box is selected.
Refer to MPLS Configuration on page 455 for more information.
3h. Select the Frame Format. Choices are Ethernet II and 802.3
SNAP. Refer to Framing Configuration on page 450 for more
information.