Test configuration – EXFO FTB-8500 Series for FTB-200 User Manual
Page 126

Summary Tabs
112
FTB-8500 Series and FTB-8120NGE/8130NGE
Test Summary
RFC 2544: Indicates the status of the running RFC 2544 test. This
setting is only available with RFC 2544 test. Possible status are:
--: Indicates that the test did not run yet.
Throughput/Back-to-Back/Frame Loss/Latency - In Progress:
Indicates that either the Throughput, Back-to-Back, Frame Loss, or
Latency test is running.
None - In Progress: Indicates that the link is down and no test is
performed.
Completed: Indicates that all selected tests are completed.
Aborted: Indicates that the test has been interrupted (stopped).
Test Configuration
Application Type: Indicates the test application type and topology
(FTB-8510B): EtherSAM (Y.1564), Frame Analyzer, BERT, RFC 2544,
Smart Loopback, or TCP Throughput (Not available on FTB-8510G).
Only BERT is available with Fibre Channel. Possible topologies are
Single Port and Dual Ports.
Test Name: The name of the test connection is used to identify the test.
A maximum of 8 characters are allowed. The default setting is TEST.
Test Description: The test description is used to describe the test case.
A maximum of 64 characters are allowed. There is no default
description.