beautypg.com

EXFO FTB-8500 Series for FTB-200 User Manual

Page 281

background image

RFC 2544 Tabs

Ethernet and Fibre Channel Application

267

Throughput Results

Frames Count

TX-to-RX/P1-to-P2/P2-to-P1/Local to Remote/Remote to Local: Gives
the number of frames for the indicated direction. P1-to-P2/P2-to-P1 is
only available with FTB-8510B.

TX Frame Count: Indicates the number of transmitted frames.

RX Frame Count: Indicates the number of received frames.

Throughput Results

Frame Size: Indicates the frame sizes used for the test. Up to seven
different frame sizes can be displayed.

Note: The “--” indicates that the result is not available because the test has not

run yet or the measured value is not valid.

TX-to-RX/P1-to-P2/P2-to-P1/Local to Remote/Remote to Local:
Gives the number of frames for the corresponding direction.
P1-to-P2/P2-to-P1 is only available with FTB-8510B.

Current Trial: Indicates the current trial number.

Units: Select the throughput result unit. Choices are bps, Bps,
Kbps, KBps, Mbps, MBps, Gbps, GBps, fps, and %. The default
unit is bps.

Layer: Select the layers used to calculate the throughput. Choices
are Layer 1,2,3, Layer 2,3, and Layer 3. The default setting is
Layer 1,2,3.

Layer 1,2,3 contains the Idle, Preamble, Start of Frame Delimiter,
MAC address, IP address, and data.

Layer 2,3 contains the MAC layer, IP layer, and data.

Layer 3 contains the IP layer, and data.

Displayed Results: Select the displayed result mode: Current,
Minimum, Maximum, or Average. The default setting is Current.

This manual is related to the following products: