Control signal for adjusting volume, Time adjustment, P. 93 – Toa SX-2000 Series User Manual
Page 93: Control input (pulse). (refer to, Control input (level). (refer to

93
EVENT SETTINGS
Function Description
12.2.4. Control signal for adjusting volume
This function changes the volume of broadcasts currently in progress.
Either a pulse or level signal can be selected as the signal to change the volume.
Pulse signal: Each time the control input is turned ON, the volume increases or decreases by the set
amount.
Level signal: While the control terminal is ON, the volume is attenuated by the set amount. After the control
input is turned OFF, the volume returns to the original level.
Example of Pulse signal-operated volume change
•
Example of Level signal-operated volume change
•
Control input
Broadcast
volume
Control input
Broadcast
volume
ON
Amount of
volume change
ON
Amount of
volume change
ON
Amount of
volume change
12.2.5. Time adjustment
This function permits the system to receive time correction signal from a master or wave clock to correct the
system's time in ±30 seconds units.
The time correction is performed by the timing of a pulse rising edge.
Time is corrected as follows:
• When time is from 0 to 29 seconds, it is corrected to 0 second.
(Example) When the SX-2000SM's time is 07:15:15, it is corrected to 07:15:00.
• When time is from 30 to 59 seconds, it is corrected to +1 minute, 0 second.
(Example) When the SX-2000SM's time is 07:15:45, it is corrected to 07:16:00.
Control input
±30 seconds correction
ON