Function description, P. 90, Refer to – Toa SX-2000 Series User Manual
Page 90

90
EVENT SETTINGS
Function Description
12.2. Function Description
12.2.1. General-purpose pattern broadcasts, General-purpose pattern broadcasts (Level)
When different control inputs turn ON, general-purpose pattern broadcasts activated by each control
input* are made simultaneously.
General-purpose patterns and control output patterns in the above example operate as follows:
• Example of general-purpose pattern operation
General-purpose pattern 1 activated when control input 1 is ON continues until control input 1 turns OFF.
General-purpose pattern 2 activated when control input 2 is ON continues until control input 2 turns OFF.
• Example of control output operation
Control output pattern 1 activated when control input 1 is ON continues until control input 1 turns OFF.
Control output pattern 2 activated when control input 2 is ON continues until control input 2 turns OFF.
The state of control outputs overlapping in control output patterns 1 and 2 continues during the period from
the time control input 1 turns ON until control input 2 turns OFF. (OR logic output)
* This timing chart also applies when general-purpose pattern broadcasts are activated by the function keys or
channel keys of the SX-2000AI, SX-2100AI, SX-2000AO, or SX-2100AO, or the function keys of the RM-
200SF, RM-200S, RM-200SA, or RM-210.
Broadcast of general-purpose pattern 1
Control output pattern 1: ON
Broadcast of general-purpose pattern 2
Control output pattern 2: ON
ON
ON
Control outputs overlapping in control output patterns 1 and 2
continue ON during this period.
Control input 1
Control input 2
(General-purpose pattern: 1, Control output pattern: 1)