Toa SX-2000 Series User Manual
Page 131

131
UTILITY
System Status Display Confirmation
[Button indication priorities when multiple statuses occur simultaneously]
(High) Emergency cutoff
CPU off
CF card error, Maintenance
Error
(Low)
Normal, Power failure (N), Emergency, Power failure (E), Initialization
[Button display priorities when multiple statuses simultaneously occur]
Error > Difference > Correct
2. AI
Displays SX-2000AI or SX-2100AI system status.
A number represents the unit number of the SX-2000AI or SX-2100AI that has been set for connection.
Clicking the button displays the detailed information screen (AI unit screen).
(Refer to
On-button indication
System status
(Blank)
No connection setting.
Correct
The SX-2000AI or SX-2100AI is operating correctly.
(Preprogrammed units match actually connected units.)
Error
The SX-2000AI, SX-2100AI, RM-200S, RM-200SA or RM-210 has failed.
Difference
Preprogrammed units do not match actually connected units.
On-button indication
System status
CF card error
CF card irregularities detected:
• CF card not inserted.
• Cannot read the CF card since the SX-2000SM's DIP switch 2 is set to ON.
• No setting data.
• Cannot read setting data.
• No EV message data.
• EV message data irregularities detected.
• Insufficient space available on CF card.
• CF card has failed.
Maintenance
Operating in maintenance mode.
• The SX-2000SM's DIP switch 2 is set to ON.
• CF card not inserted.
Initialization
Initialization in progress.
CPU off
The system is in the CPU off state.
Since the RM-200S, RM-200SA, RM-210, SX-2000CI and SX-2000CO are reset
in the CPU off state, they are disconnected.
Emergency cutoff
One of the SX-2000AO units is in the emergency mode that cuts off 24V DC to
allow emergency broadcasts to go through.
Error
The SX-2000SM has failed.