EVENT SETTINGS
RM Event Settings (RM-200S, RM-200SA)
Notes
• Only the "Emergency broadcast pattern start" function can be assigned to the covered key.
• Pressing the covered key allows the General urgency all-call broadcast (All zone broadcast by way of
analog transmission not via the Software control) to be made regardless of whether the function of the
covered key is set to "None" or "Emergency broadcast pattern start" on this Setting Software. For details,
refer to the separate Operation Manual, "Making General Urgency All-calls."
• The setting procedures for the Function (2) and contents (3) and (4) are the same as those described on
RM-200SF settings
(2) Function
Select functions to be assigned to the Covered key and Function keys on the RM-200S and RM-200SA,
and the Function keys on RM-210*.
If the selected function needs particular settings, they are displayed on the "Contents."
* Assignable functions to the RM-210 differ depending on the type of remote microphone the RM-210 is
connected to. The same functions as those assigned to the remote microphone (RM-200SA or RM-200S)
can be assigned to the RM-210.
None (default), Zone selection (Pattern), Zone selection (Individual),
Zone selection clear, BGM pattern change/end*
1
, General broadcast*
1
,
RM broadcast status, Lamp test*
2
*
1
Corresponding patterns must be created in advance to select these items.
*
2
RM-200SA only
• Following functions are available when the emergency broadcasting function is
set to "Used" in the "Basic Settings" and the type of RM-200SA set to
"Emergency/General" in the "System Settings."
Emergency broadcast pattern start, Emergency broadcast pattern stop,
Emergency sequence stop, Emergency sequence phase shift, Emergency
reset
• Following function can also be selected when the Surveillance function has
been set to "Used" in the "Basic Settings."
Failure output receipt, Failure output reset