"LINK" LED indicators on the MIMO88's front panel have different behaviours, depending on whether the
unit operates in 8x8, 16x16 MASTER or16x16 SLAVE mode and on its status:

 8x8 MASTER mode: LED off

 16x16 MASTER mode:

o Fast flashing green LED: correct MASTER-SLAVE connection, error-free communication
o Fast flashing LED, alternating between green and red: communication error in the

MASTER-SLAVE connection

o Slow flashing LED, alternating between green and red: no BUS LINK-connected SLAVE

is detected or it's another MASTER unit

 16x16 SLAVE mode:

o Fast flashing orange LED: correct MASTER-SLAVE connection, error-free communication
o Fast flashing LED, alternating between orange and red: communication error in the

MASTER-SLAVE connection

o Slow flashing LED, alternating between orange and red: no BUS LINK-connected

MASTER is detected or it's another SLAVE unit


If MASTER-SLAVE connection is invalid, a broken link symbol appears (green and red flashing
rectangles) in EclerNet Manager, in the MASTER device status window. Possible causes are:

 no device connected to the BUS LINK of the MASTER unit

 connected equipment is another MASTER unit (its rear panel switch is in MASTER position

instead of SLAVE)