Ecler ECLERNET MANAGER User Manual
Page 50
50
Device configuration. See (1)
Network parameters configuration. See (2)
Digital AES/EBU input: a VALID message is displayed when a valid
AES/EBU signal is input in the device.
Provides a
12 dB trim adjustment
(1) Device configuration.
Clicking on the configuration edit icon opens the parameter setting
window:
For a NPA Series amplifier, adjustable parameters are:
Output Mode: STEREO/BRIDGE/PARALLEL.
Selects the operating mode of the device amplified outputs: stereo, bridged or parallel (see the
hardware NPA Series owner’s manual).
Volume Link: ON/OFF.
Determines if both channels’ volume controls of an amplifier are linked (ON) or independent
(OFF).
Anticlip Mode: SOFT/MID/HARD.
The protection system against saturation can operate in SOFT, MID, or HARD mode.
Maximum Mains Voltage: 200 to 280 V AC (version for 230 V AC nominal voltage.)
Determines the AC mains voltage threshold above which overvoltage occurs.