beautypg.com

Ecler ECLERNET MANAGER User Manual

Page 50

background image

50

Device configuration. See (1)

Network parameters configuration. See (2)

Digital AES/EBU input: a VALID message is displayed when a valid
AES/EBU signal is input in the device.
Provides a

12 dB trim adjustment


(1) Device configuration.
Clicking on the configuration edit icon opens the parameter setting
window:


For a NPA Series amplifier, adjustable parameters are:

Output Mode: STEREO/BRIDGE/PARALLEL.

Selects the operating mode of the device amplified outputs: stereo, bridged or parallel (see the

hardware NPA Series owner’s manual).

Volume Link: ON/OFF.

Determines if both channels’ volume controls of an amplifier are linked (ON) or independent

(OFF).

Anticlip Mode: SOFT/MID/HARD.

The protection system against saturation can operate in SOFT, MID, or HARD mode.

Maximum Mains Voltage: 200 to 280 V AC (version for 230 V AC nominal voltage.)

Determines the AC mains voltage threshold above which overvoltage occurs.