Below is the section for programming the function to be performed by the LEVEL rotary knobs on the
front panel and the rear panel GPI ports:


The front panel LEVEL controls are displayed as KNOB 1 to 4 (or 6, depending on model). To the right of
each of them is displayed the value of the front panel hardware LEVEL control, read in real time, from 0
to 100 (in this example 58, 28, 2, etc.)
For each of them, the drop-down menu allows to select the control function of certain audio inputs or
outputs of the unit:

After selecting the type of volume control (INPUT or OUTPUT), the inputs or outputs simultaneously
affected by each control have to be checked in boxes 1, 2, 3, 4, 5 and 6. Clicking with the mouse
activates (green) or deactivates them. In the above example, we see the following control settings:

 LEVEL 1 controls the inputs 1 and 2 levels
 LEVEL 2 controls the inputs 3 and 4 levels

 LEVEL 3 controls the input 5 level

 LEVEL 4 controls the outputs 3 and 4 levels

 LEVEL 5 controls the output 2 level

 LEVEL 6 controls the output 6 level

Note: a LEVEL control can simultaneously control multiple inputs and outputs, but NOT the other
way round: the application automatically manages that one input or output is associated with a single
control knob, and not simultaneously with several ones

The unit's GPI ports (0-10 VDC control ports) on the rear panel are displayed as GPI 1 to 4 (or 6,
depending on model). To the right of each of them is displayed the value of the signal received on the
central pin of each GPI port, read in real time (0 to 100).
For each of them, the drop-down menu allows to select the control function from the following options:

 INPUT VOL.: volume control of one or more audio inputs of the unit. The boxes of the targeted

inputs must be checked: clicking with the mouse activates (green) or deactivates them. In the
following example the GPI #2 controls the volume of the inputs 1 and 2: