The light indicator on the left of the module indicates the active or inactive state of the DUCKER function
(activation threshold exceeded). It lights up in green when the DUCKER function is active.
The module rotary knobs are used to adjust the operation of the DUCKER function:
THRESHOLD: activation threshold. When the module's input signal (INPUT selector) exceeds
this threshold, the DUCKER function is activated, sending the signal to the destination zones
and attenuating the other audio signals sent to the same zones (-80 to 0dB)
DEPTH: attenuation applied on the rest of the signals sent to the destination zone(s) during
the time the DUCKER function is active (0 to 80dB)
ATTACK: attack time. Determines the time the DUCKER takes to respond when the level
rises above the threshold (activating the attenuation of other signals in the destination zones).
The range extends from 5 ms to 2 sec.
HOLD: amount of time the DUCKER function remains active once the signal falls back below
the detection threshold. The setting range extends from 10 ms to 3 sec.
RELEASE: determines the time elapsed until attenuation stops after the time fixed for HOLD.
In this case, the range extends from 50 ms to 3 sec.