Amplifier
total
Gain: 26 / 32dB
Output Mode: SINGLE / BRIDGE / PARALLEL.
In SINGLE mode, a channel is absolutely independent of the other amplifier channels for all
settings (input selection, volume, EQ settings, compressor, etc.). In this mode, each channel has
its own control window in EclerNet Manager application.
In BRIDGE and PARALLEL modes, channels are linked, set and controlled by pair, appearing in
software as a unique control panel for each pair of linked channels. Possible pairs are always
made of consecutive channels: 1&2, 3&4, 5&6 (4 or 6 channels, depending on the NXA device).
Compressor Mode: COMPRESSOR/VPEAK LIMITER (voltage peak limiter).
It determines how the GUI of the channel compressor will look, with a choice between a classic
compressor and a voltage peak limiter for the output signal of the amplifier (see section 6.6.
COMPRESSOR).
9.3.9. Copying and pasting settings between channels
Copy Channel Data and Paste Channel Data icons (
), located in the upper right corner of the
control panel of each device channel, are used to copy all settings from one amplification channel in
temporary memory and paste them in another amplification channel.
Considerations:
Channel copying and pasting can be done within a single device or from a device channel to a
channel of another device
In the latter case, copying and pasting operation can only be made between channels of the
same device series (you can not copy a channel from a NPA amplifier and paste it into a NXA
amplifier, or vice versa)
To clone the full configuration of all channels from one device to another, use Copy Device
Preset and Paste Device Preset from the icons to the right of the preset name in the upper
section of the device configuration