Ecler ECLERNET MANAGER User Manual
Page 182
182
We will have therefore to include 4 buttons in our UCP, with the following control information:
Key 1: select Preset 1, value 12
Key 2: select Preset 3, value 37
Key 3: select Preset 6, value 62
Key 4: select Preset 7, value 87
In our example, each one of these buttons has to operate the virtual control #16, which is the one we
selected as control for our virtual selector in the REMOTES section:
When you press one of these buttons, the virtual control #16 should take the corresponding value among
the 4 ones in the table above, value 12 for the first button, value 37 for the second button, and so on. To
enable this function for each button, you must follow the following steps (for the previous example):
Select the virtual control #16 for
Param
in the Properties
Check the
Push Only
(*) checkbox
Enter the corresponding value (12, 37, 62 or 87) in the
Data
field
(*) A standard button always sends a value of 100 when pressed and 0 when released, an ideal behavior
to recall a specific preset or activate a MUTE. When it's necessary to send a single specific value when
pressing the button and nothing when releasing it, as it is the case with this Presets selector, the Only
Push checkbox should be checked.
The settings for each button could therefore be: