For a NPA Series amplifier, adjustable parameters are:
Amplifier
total
Gain: 26 / 32 / 38 dB
Vpeak Limiter Threshold: maximum peak output voltage to which the equipment limiter reacts.
40
to
119 V/OFF for NPA4000T
40
to
99 V/OFF for NPA2500T
Maximum Load/Minimum Load: between 0.2 and 100 ohms. Load measurement range outside
which the load impedance alarm (LOAD) is triggered and counted (COUNT).
Enable Load Alarm:
enables/disables the triggering of the load impedance alarm.
Additionally, there are two icons named “Copy Channel Data” and “Paste
Channel Data” in the control window of each device channel (upper right part).
Clicking on “Copy Channel Data” in a channel (source channel) stores all
parameters in a temporary memory.
Clicking on “Paste Channel Data” in a channel copies in the destination channel
the parameters stored temporarily during the last “Copy Channel Data”
operation, configuring the destination channel like the source channel.
6.1.2. NZA series detailed view
The top section of the detailed window provides the following items:
Device model and name
Device power switch
Status monitoring and alarms window. See 5.4 Table of status
monitoring and alarm icons
Active Preset window: indicates the Preset currently active in the
device (See section: 5.1. Reduced view)
Presets management icons:
Save Device Preset (saves the current Preset)
Copy Device Preset (copies the current Preset)
Paste Device Preset (pastes the previously copied Preset)
(See section: 5.1. Reduced view)