LED indicators can also be associated with virtual controls and you can define the Data value such
controls should have for the LED to light up.

In the following example the virtual control #16 is associated with two LED indicators, lighting the first
one when the control takes the value 62 and the second when the virtual control #16 is equal to 87. In
both cases, the value 62 or 87 of the Data field has been manually entered:











Please note that when a LED is linked to a parameter that can only take two values, 0 or 100, off or on,
the Data field is unavailable because it's not possible to freely assign a specific value to light the LED. In
the following example this happens when you link a LED to a MUTE function, which can only have two
possible values: