GPI: GPI port that it is connected to the additional hardware button or switch
Type:
o NONE: no MUTE function assigned
o X-FOCUS MUTE: the button or switch is associated with the MUTE function of the crossover
point between the input currently selected by the INPUT control and assigned output
(destination zone)
Additional options when the X-FOCUS MUTE type is selected are:
o Polarity (DIRECT/INVERSE): determines how the received signal is interpreted in the GPI (0
or 10 VDC): function is activated for 0 VDC and deactivated for 10 VDC or vice versa.
o Mode: operating mode of the button or switch:
PUSH: one state when the key is pressed (closed contact) and the opposite state
when the key is not pressed. The possible states are MUTE ON and MUTE OFF
TOGGLE: each push of the button toggles the state between MUTE ON and MUTE
OFF.