Select the trigger input (GPI, virtual control, MPAGE16 station key or event output) you want from
the dropdown list.

POLARITY: select the detection polarity for trigger or input stimulus, DIRECT/REVERSE:

o DIRECT: for rising edge-triggering: from 0VDC to 10VDC for a GPI, when pressing an

UCP key, etc.

o INVERSO: for falling edge-triggering: from 10VDC to 0VDC for a GPI, when releasing an

UCP key, etc.


Note: For example, a Preset recall has to be done with a rising edge (0 to 1), so it is
recommended to use a positive logic type.

LOGIC:

o the active state of the event is considered a “1” or high level (positive logic)
o the active state of the event is considered a “0” or low level (negative logic)

DELAY: period of time between the trigger detection and the switch to the active state of the
event

HOLD: time during which the event is held in its active state

RETRIGGER: check box to validate the event re-triggering, which provides the following options:

o checked: once an event trigger is detected, if a second stimulus of the same trigger is

detected before the end of the hold time, process is reset, starting over the time count of
delay time + hold time.

o unchecked: any trigger stimulus received after the first one will be ignored if the hold time

period is not elapsed


Finally, we must define what will be the output or destination of the event and its PUSH or TOGGLE
behavior, here again exactly as we proceed in the case of a simple digital event: