3-37
3
LK-G-M-NO3-E
3 Function Settings
Setting the Common Function
This section describes the functions common to each program No.
List of Functions and Function Nos.
* The shaded cells
are set by default.
* Function "F" sets the number of data and accumulation rate as a sub-function.
List of Default Values and Setting Ranges
Function
Function
Function No.
Reference
Function display
0
1
2
3
4
5
page
A
Sampling rate
20 µs
50 µs
100 µs
200 µs
500 µs
1000 µs
3-39
Y LE
20
50
100
200
500
1000
b
Mutual interference
prevention
OFF
ON
3-40
AltEr
oFF
on
Timing synchronization
Asynchronous Synchronous
3-41
Syn
n-Syn[
Syn
d
Comparator output format
Normal
HOLD
Off-delay
3-42
o-For
nor al
xoLd
delay
E
Strobe time
2 ms
5 ms
10 ms
20 ms
3-43
S-t
E
2
5
10
20
F
Data storage
OFF
OUT1
OUT2
OUT 1 , 2
3-44
d-Str
oFF
oUt1
oUt2
oUt1.2
Refer to "Accumulating the Measurement Value in the Memory (Data Storage Function)"
(page 3-54).
Function
Item
Settable range
Default value
Remarks
A
Sampling rate
20/50/100/200/500/1000 µs
200 µs
b
Mutual interference prevention
ON/OFF
OFF
Timing synchronization
Synchronous/asynchronous
Asynchronous
d
Comparator output format
Normal/hold/delay
Normal
E
Strobe time
2/5/10/20 ms
2 ms
F
Data selection
OFF/OUT1/OUT2/OUT1.2
OFF
Number of data
1 to 65536
65536
Accumulation rate
1/2/5/10/20/50/100/200/500/1000
x 20