KEYENCE LK-G Series User Manual
Page 32

1-12
1
LK-G-M-NO1-E
1 Before Use
■
LK-G155/LK-G150/LK-G157/LK-G152
The measurement range is shown in the figure below.
* The value inside the parentheses ( ) is when the sampling rate is 20 µs. Note that the
measurement range narrows, disabling measurements at the reference position.
• The laser emission LED at both diffuse reflection and specular reflection lights in
green within ±2 mm of the reference position, and lights in orange in the other
positions in the measurement range.
• Select the mounting mode (
page 3-12) according to the installation conditions.
The measurement range when measuring a mirror surface or a glass surface at the time of
specular reflection setup is between +39 (NEAR side) to –24 mm (FAR side). When the
sampling rate is 20 µs, the value becomes +39 (NEAR side) to +22 mm (NEAR side).
LK-G150
M4r40 mm or more
• Installation procedure
LK-G150
LK-G150
• Diffuse reflection setup
• Specular reflection setup
Reference
distance
150 mm
Reference
distance
0 mm
+39mm
Measurement range
–39mm
(+22mm)
+40mm
Measurement range
–40 mm
(+22mm)
Reference
distance
147.5 mm
Reference
distance
0 mm
17°
Reference
Note