beautypg.com

Measurement control command format, Measurement control command, Format -8 – KEYENCE LK-G Series User Manual

Page 138: Lk-g-m-no5-e

background image

5-8

5

LK-G-M-NO5-E

5 RS-232C

Measurement Control Command Format

This section describes the command format to control the measurement such as incoming
commands that the LK-G Series can receive during the measurement, and the response
commands that are to be sent after properly processing the incoming commands.

These commands are accepted only when the controller is in the "Normal mode".

Note

Incoming command

Operation

Response command

Symbol

Measurement
value output

M a

a

CR

,

[

]

,

M

Clearing statistics

D Q

,

a

CR

D Q

,

a

CR

Timing ON/OFF

T p

,

a

CR

T p

CR

Auto-zero ON

V a

CR

V a

CR

W a

CR

W a

CR

Auto-zero OFF

Reset

V R

,

a

CR

V R CR

Panel lock

K

L

,

p

CR

K

L CR

Program change

P W

,

o

CR

P W CR

Program check

P R CR

P R

,

o

CR

h

h

h

h

h

h

h

h

h

h

h

h

h

h

CR

h

h

CR

d

d

d

d

d

d

d

d

d

d

,

A

s

,

[

]

A O

N

h

h

h

h

h

h

h

h

,

[

]

h

h

h

h

h

h

h

h

,

[

]

h

h

h

h

h

h

h

h

CR

h

h

h

h

a : OUT number

ddddd : Number of the accumulated data

hhhhhhhh : Measurement value

p : ON/OFF setting

mmmmmm : Number of data

o : Program No.

s : Accumulation status

Statistical

result output

CR

D O

D O

,

a

CR

A O

,

a

,

,

,

,

h

h

,

a

h

h

h

h

h

h

h

h

,

h

h

h

h

h

h

h

h

,

h

h

h

h

h

h

h

h

,

h

h

h

h

h

h

h

h

,

h

h

CR

m m m m

,

m m

m m m m

m m

m m m m

,

m m

m m m m

,

m m

Starting the data
storage

A S CR

A S CR

Stopping the data
storage

A P CR

A P CR

Initializing the
data storage

A Q CR

A Q CR

Outputting the
data storage data

Data storage

accumulation

status output

A N CR

The shaded cells indicate the setting values or measurement values.

··

·