beautypg.com

Timing chart, Timing chart -21 – KEYENCE LK-G Series User Manual

Page 151

background image

5-21

5

LK-G-M-NO5-E

5 RS-232C

Timing Chart

The timing chart of the incoming/response command is shown below.

The t-time is identified as follows.

[ms]

* The response speed slows during the communication with the Setup support software "LK-

Navigator".

Command

Sampling rate (T)

20 µs

Other than 20 µs

Measurement
control

M

8

2

PW

When connecting one head

60

(T x 10)+50

When connecting two heads

50

(T x 10)+60

DO

20

5

Other than above

10

3

Setting/check

S W , H D

60

Other than above

5

Mode change

Q0

5

R0

70

Reception

Incoming command

Response

t

Response command