Functions of the input and output signals, Functions of the input and output, Signals -7 – KEYENCE LK-G Series User Manual
Page 119

4-7
4
LK-G-M-NO4-E
4 Input/Output Terminals
Functions of the Input and Output Signals
The following table shows a list of program numbers and how they relate to the status of
terminals P1 through P3.
Comparator output
Alarm output
Input and output signals for measurement control
Auto-zero input
Program No. switch input
Refer to 4-2 for the layout of each terminal.
Name
Description
Reference
page
Tolerance comparator
output
(HI, GO, LO)
Outputted according to the tolerance comparator results.
Name
Description
Reference
page
Alarm (N.C.) output
Turned on when "–FFFFFF" is displayed due to the alarm
processing (the NPN or PNP open-collector output
transistor is off). Turned off when the normal value is being
held.
Name
Description
Reference
page
TIMING input
Performs an external synchronization input of the
measurement mode.
RESET input
Resets the measurement value.
Name
Description
Reference
page
ZERO input
Sets the current measurement value to zero.
Name
Description
Reference
page
P1, P2, P3
Changes the program No. by external commands.