3 Function Settings

Setting the Trigger Condition

Trigger 1 and trigger 2 differ in terms of the sampling period during which the measurement
value is retained in the measurement mode. The offset value is set for the measurement value
that underwent a measurement mode process and the auto-zero process.

Refer to "Using

the Hold Function (Measurement Mode)" (page 3-25) for the details of the timing difference.

1

Hold down the

key, and select "

oUt-1

" with the

key.

2

Press the

key, and select the function "

E

" with the

key.

Select Hold.

3

Press the

key, and select "

E-1

" with the

key.

"Trigger 2" is selected in this example.

4

Press the

key to register the setting. Press the

key to return to the measurement state.

Function No.

Trigger

Function

Normal

Peak hold / bottom
hold / peak-to-peak
hold / average hold

Sample-and-hold

E-0

TIM1

Trigger 1

Holds the internal
measurement value on
the rising edge of the
TIMING signal.

The sampling period is
from the rising edge of
the timing signal until
the next rising edge.

Holds the internal
measurement value on
the rising edge of the
TIMING signal.

E-1

TIM2

Trigger 2

The sampling period is
from the falling edge of
the timing signal until
the next rising edge.

On the rising edge of
the TIMING signal, the
sensor takes a number
of samples equal to
the moving average
value and the resulting
internal measurement
value will be held.

OUT1

HI

GO

LO

HI

GO

LO

TIM

OUT2

TIM

OUT1

HI

GO

LO

HI

GO

LO

TIM

OUT2

TIM

OUT1

HI

GO

LO

HI

GO

LO

TIM

OUT2

TIM