Setting the head, List of functions and function nos, List of default values and setting ranges – KEYENCE LK-G Series User Manual
Page 61: Setting the head -3, List of functions and function nos -3, List of default values and setting, Ranges -3

3-3
3
LK-G-M-NO3-E
3 Function Settings
Setting the Head
This section describes the settings related to the sensing for stable detection.
List of Functions and Function Nos.
* The shaded cells
are set by default.
List of Default Values and Setting Ranges
Function Function
Function No.
Reference page
Function
display
0
1
2
3
4
A
Light intensity
adjustment
AUTO
MANUAL
3-5
able
Auto
anual
b
Measurement
mode
Normal
Translucent
object
Transparent
object
Transparent
object 2
Multi-reflective
object
3-7
EAS
nor al
KAlF-t
tran-i
tran-2
rs
Alarm process
Count setting (
[oUnT
, 0 to 999, 8)
Level (
LEVEL
, 0 to 9, 4 )
3-8
ALAr
d
ABLE
calibration
START/STOP
3-10
aBle-t
STart
/
stop
e
Mounting
mode
Diffuse
reflection
Mirror
reflection
3-12
oUnt
d FF-S
rr-S
Function
Item
Settable range
Default value
Remarks
A
ABLE
Auto/Manual
AUTO
Upper limit of control
1 to 99
99
Lower limit of control
1 to 99
1
b
Measurement mode
Normal / Translucent object / Transparent object
/ Transparent object 2 / Multi-reflective object
Normal
[
Number of times of processing
0 to 999
8
Level
0 to 9
4
d
ABLE calibration
START/STOP
-
e
Mounting mode
Diffuse reflection / Mirror reflection Diffuse
reflection