beautypg.com

5 pr 1721/42 interbus-s interface, Pr 1721/42 interbus-s interface – Rice Lake PR5230 Fieldbus Transmitter User Manual

Page 77

background image

PR 5230 Instrument Manual

Installing the Instrument and Plug-in Cards

Sartorius

EN-77

4.4.5

PR 1721/42 InterBus-S Interface

The InterBus-S interface PR 1721/42 is a plug-in card for mounting in slot 2, see Chapter 4.4.1.
The interface is based on the InterBus chip technology and enables transfer rates of 500 kbit/s and 2 Mbit/s.

Internal connection 34- pin connector on flat cable for

slot 2

External connection 6-pin (IN) and 7-pin (OUT) plug-in

terminal block.

D01 D01 DI1 DI1 GND S D02 D02 DI2 DI2 GND C S

C = Con_Test
S = Screen
Transfer rate

500 kbit/s

Topology

Bus as a closed ring

Protocol

InterBus-S master-slave
fixed telegram length, deterministic
cyclical process data transmission with
max. 10 words I/O.

Cable

InterBus, color: green
3x 2 twisted pairs,
common shield

Lead termination

Not required, due to active ring topology

Cable impedance 150 ¥

Certificates

From INTERBUS Club e. V.: Compatibility
with InterBus standard.
IEC 61158 (Parts 3 to 6)
EN 50254 (DIN 19258)
Suitable for industrial applications
CE, UL & cUL

Dimensions

(LxWxH)

87 x 55 x 15 mm

Potential isolation Yes, optocoupler and DC/DC converter

Weight

35 g

Cable length

400 m
(between two remote bus sharing units).
Overall length: 13 km