Transmitter in Field Housing
PR 5230 Instrument Manual
EN-12
Sartorius
2
Transmitter in Field Housing
The instrument is equipped with a 128 x 64 pixel display for weight values with max. 6 digits and additional
status indication.
2.1
Overview of the Instrument
-
Accuracy 10,000 e (Class III) for the weighing electronics
-
High-speed conversion with response times from 5 msec
-
Weight indication with status by monochrome 128 x 64 pixel display
-
3 function keys in the housing, function configurable
-
Wall-mounted stainless steel housing, with IP 66 protection
-
LAN adaptor with 10/100 Mbit/sec for data transfer, calibration, parameterization
-
RS-232 interface, built-in; for connecting e.g. a printer or a remote indicator
-
RS-485 interface, built-in; for connecting e.g. PC
-
Expansion possible by addition of following plug-in circuit boards (3 slots):
- Analog output board PR 5230/06
- Load cell junction board PR 5230/22
- Interfaces PR 1721/4x
-
3 opto-decoupled outputs (optional)
-
3 configurable relay outputs with change-over contact
-
3 configurable optocoupler inputs, potential-free internal supply possible (optional)
-
Galvanically isolated interfaces (except RS-232)
-
Wide range power supply for 100 to 240 V AC, protection class I (protective earth)
-
Version PR 5230 for 24 V direct current
-
Version PR 5230 with intrinsically safe load cell supply (optional)
-
Plug-in connections inside the instrument for load cells, inputs/outputs, LAN adaptor, serial interfaces
-
Calibration using PC tool (Browser/VNC)
-
Calibration using weights, by entering mV/V values, or directly, using load cell data ("smart calibration")
-
Software configuration of the interface cards, e.g. for remote display or printer
-
Analog test for the weighing electronics
Communication Protocols
For the internal RS-232 or RS-485:
Fieldbus Slave (accessories):
-
Remote display protocol
-
PR 1721/41
ProfiBus-DP
-
Printer
-
PR 1721/42
InterBus-S
-
J-Bus/ModBus (Slave)
-
PR 1721/44
DeviceNet
-
SMA protocol
-
PR 1721/45
CC-Link
-
xBPI protocol
-
PR 1721/46
ProfiNet I/O
-
Asycom protocol
-
PR 1721/47
EtherNet-IP
For the internal LAN:
-
ModBus-TCP
-
Ethernet-TCP/IP
-
OPC