beautypg.com

Rice Lake 920i Programmable HMI Indicator/Controller - Analog Output Card User Manual

Analog output card installation instructions

background image

Analog Output Card Installation Instructions

PNs 67602 and 103138

Use the following procedure to install analog output cards in 820i and 920i indicators:

1. Disconnect indicator from power source.

WARNING

Disconnect power before removing indicator backplate.

2. Place indicator face-down on an anti-static work mat. Remove screws that hold the backplate to the

enclosure body.

CAUTION

Use a wrist strap to ground yourself and protect components from electrostatic discharge (ESD) when
working inside the indicator enclosure.

3. Carefully align the large connector on the bottom side of the option card with the indicator option card slot

(J5 or J6 on the 920i, J6 on the 820i.). Press down to seat the option card in the CPU board connector.

J6

Figure 1. Installing Option Card Onto CPU Board

4. Use the screws and lock washers provided in the option kit to secure the other end of the option card to the

threaded standoffs on the CPU board (see Figure 1).

5. Make connections to the option card as required. Use cable ties to secure loose cables inside the enclosure.
6. Set the mode selection jumper (see Figure 2) for voltage or current output.
7. Once cabling is complete, position the backplate over the enclosure and reinstall the backplate screws. Use

the torque pattern shown in the indicator Installation Manual to prevent distorting the backplate gasket.
Torque screws to 15 in-lb (1.7 N-m).

8. Ensure no excess cable is left inside the enclosure and tighten cord grips.
9. Reconnect power to the indicator.
10. Configure the analog output card as described on page 3.

69089 Rev B

December 2014