Rice Lake 320IS Plus Intrinsically Safe Digital Weight Indicator - Installation Manual User Manual
320is plus, Installation manual
Table of contents
Document Outline
- 1.0 Introduction
- Safety
- 1.1 Overview
- 1.2 Factory Mutual Approval
- 1.3 Operating Modes
- 1.4 Front Panel Keypad
- 1.5 Front Panel Configuration
- 1.6 LED Annunciators
- 1.7 Indicator Operations
- 1.7.1 Toggle Gross/Net Mode
- 1.7.2 Toggle Units
- 1.7.3 Zero Scale
- 1.7.4 Acquire Tare
- 1.7.5 Remove Stored Tare Value
- 1.7.6 Alternate Method to Remove Tare
- 1.7.7 Acquire Parts Sample
- 1.7.8 Display Part Weight
- 1.7.9 Display or Change Time/Date
- 1.7.10 Print Ticket
- 1.7.11 Display or Change Setpoint Value
- 1.7.12 Turn Setpoint On or Off
- 1.7.13 Display or Clear Accumulator
- 2.0 Installation
- 2.1 Unpacking and Assembly
- 2.2 Enclosure Disassembly
- 2.3 Hazardous Area Installation of the 320IS Plus
- 2.3.1 Power Supply to Indicator
- 2.3.2 AC Power Wiring
- 2.3.3 Battery Option
- 2.4 Cable Connections and Installation
- 2.4.1 Braided Power Cable Connection with Ferrite Core
- 2.4.2 Braided Power Cable Connection Without Ferrite Core
- 2.4.3 Braided Load Cell Cable Connection
- 2.4.4 Foil Load Cell Cable Connection
- 2.4.5 Load Cells
- 2.5 Fiber Optics Installation
- 2.5.1 Assembling Fiber Optics Connectors
- 2.6 Enclosure Reassembly
- 2.7 Control Drawings
- 3.0 Configuration
- 3.1 Configuration Methods
- 3.1.1 Revolution Configuration
- 3.1.2 EDP Command Configuration
- 3.1.3 Front Panel Configuration
- 3.2 Menu Structures and Parameter Descriptions
- 3.2.1 Configuration Menu
- 3.2.2 Format Menu
- 3.2.3 Calibration Menu
- 3.2.4 Serial Menu
- 3.2.5 Program Menu
- 3.2.6 Print Format Menu
- 3.2.7 Setpoint Menu
- 3.2.8 Analog Output Menu
- 3.2.9 Version Menu
- 4.0 Calibration
- 5.0 EDP Commands
- 5.1 The EDP Command Set
- 5.1.1 Key Press Commands
- 5.1.2 Reporting Commands
- 5.1.3 The RESETCONFIGURATION Command
- 5.1.4 Parameter Setting Commands
- 5.1.5 Normal Mode Commands
- 5.1.6 Batching Control Commands
- 5.2 Saving and Transferring Data
- 5.2.1 Saving Indicator Data to a Personal Computer
- 5.2.2 Downloading Configuration Data from PC to Indicator
- 6.0 Print Formatting
- 7.0 Setpoints
- 8.0 Appendix A
- 8.1 Error Messages
- 8.1.1 Displayed Error Messages
- 8.1.2 Using the XE EDP Command
- 8.2 Status Messages
- 8.2.1 Using the P EDP Command
- 8.2.2 Using the ZZ EDP Command
- 8.3 Continuous Output (Stream) Format
- 8.4 ASCII Character Chart
- 8.5 Conversion Factors for Secondary Units
- 8.6 Digital Filtering
- 8.6.1 DFSENS and DFTHRH Parameters
- 8.6.2 Setting the Digital Filter Parameters
- 8.7 Analog Output Calibration
- 8.8 Test Mode
- 9.0 Appendix B
- 9.1 Unpacking and Assembly
- 9.2 Enclosure Disassembly
- 9.3 Installation of the I/O Module
- 9.3.1 AC Wiring/Installation
- 9.3.2 EDP and Printer Ports
- 9.3.3 RS-232 Communications
- 9.3.4 RS-485 Communications
- 9.3.5 RS-422 Communications
- 9.3.6 20mA Current Loop
- 9.4 Fiber Optics Assembly
- 9.5 Analog Outputs
- 9.6 Digital Inputs
- 9.7 Relay Contact Outputs
- 9.8 I/O Module Mounting
- 9.9 320IS Plus Specifications
- 320IS Plus Limited Warranty