Input area, Description of the i/o area (read / write window), Pr 5230 instrument manual fieldbus interface – Rice Lake PR5230 Fieldbus Transmitter User Manual
Page 191

PR 5230 Instrument Manual
Fieldbus Interface
Sartorius
EN-191
9.2
Description of the I/O Area (Read / Write Window)
Input Area 
Data transmission from the master to the PR 5230 (slave) is via the input area. 
Weight or data requests are transmitted to the slave by the master. 
The master has write access; the slave has read access. 
Byte Name
Description
0
Write_Value (MSB)
e.g. limit value
1
:::
"
2
:::
"
3
Write_Value (LSB)
"
4
Read_Value_Select
e.g. gross weight
5
Write_Value_Select
Write:
Limit 1 On
6
free
Res M3 Res M2 Res M1 free
Set M3 Set M2 Set M1
Free/digital outputs
7
Get 
FixTare 
Set 
FixTare 
Res 
Power 
Res Test Set
Test
Res 
Tare 
Set 
Tare 
Set Zero
Control byte,
response to
0->1
transition
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
 
The 
control byte
activates the corresponding action in the instrument with a set bit.
After execution of the operation, the bit should be reset.
Variable
Function
Write_Value
The weight value is transmitted as a binary 32-bit value with plus or minus sign 
Data type: 
DINT
Read_Value_Select For selecting the value sent by the instrument 
Write_Value_Select For selecting the function to be executed by the instrument 
GetFixTare 
The gross weight is copied into the fixtare memory.
SetFixTare
Taring is performed using the value stored in the fixtare memory.
ResPower
The
Power_Fail
bit in the output area is deleted.
ResTest
The test operating mode is finished.
SetTest
The test operating mode is started. Now the test value can be read out by reading the 
gross weight. 
ResTare
Tare is reset.
SetTare
The scale is tared.
SetZero
The scale is set to zero.
Res M1…3
Marker 1…3 is reset
Set M1…3
Marker 1…3 is set