11 configuration print-out, Configuration print-out, Er 11 – Rice Lake PR5230 Fieldbus Transmitter User Manual
Page 203: Pr 5230 instrument manual configuration print-out
PR 5230 Instrument Manual
Configuration Print-out
Sartorius
EN-203
11
Configuration Print-out
The print-out can be started by [Configuration Printout] or using the keys
and
via VNC (click one
after another).
Prerequisite:
Printer is connected, [Setup]-[Serial ports parameter]-[Printer]: e.g. [Builtin RS232].
Printing parameter has been set, [Setup]- [Printing parameter].
Configuration of PR5230
====================================
Printed :2009-10-14 11:36:27
Firmware (Beta) :Rel. 00.90.00.58374
: 2009-10-14 10:51
Application : Rel. 01.00.00
2009-09-04 10:57
Bios (Beta) :Rel. 00.98.00.56454
2009-08-24 16:42
Boardnumber : 327924490
HW-Options
====================================
Builtin : RS485
Builtin : RS232
Builtin : digital i/o
PR1721/41 : Profibus-DP
PR5230/W1 : ADC
Fieldbus parameter
====================================
Fieldbus protocol : Profibus-DP
Profibus-DP address: 3
PR1721/41 Profibus-DP version
====================================
Fieldbus sw version: 02.01
Module sw version : 02.01
Serial number : 2685112110
Operating parameter
====================================
Address : A
PIN : 0
Sequencenumber : 1092
Set Tare Key : tare & reset tare
Set zero key :reset tare on zeros
Printing parameter
====================================
Printing mode : Triggered
PrintlayoutItem1 : CR/LF
PrintlayoutItem2 : Grossweight
PrintlayoutItem3 : Netweight
PrintlayoutItem4 : Tareweight
PrintlayoutItem5 : -none-
PrintlayoutItem6 : -none-
Limits
====================================
Limit 1 on : 100 kg
Action :set marker 1 X64=1
Condition :no condition -----
Limit 1 off : 100 kg
Action :clr marker 1 X64=0
Condition :tare activ X58=1
Limit 2 on : 300 kg
Action : -no action-
Limit 2 off : 290 kg
Action : -no action-
Limit 3 on : 150 kg
Action : -no action-
Limit 3 off : 100 kg
Action : -no action-
Digital I/O
====================================
Output 1 :act. diginp 1 X00=1
Output 2 :marker bit 2 X65=1
Output 3 :cal activ X57=1
Input 1 on :select net X72=1
Condition :no condition -----
Input 1 off : -no action-
Input 2 on :select gross X72=0
Condition :no condition -----
Input 2 off : -no action-
Input 3 on : -no action-
Input 3 off : -no action-
Analog out
====================================
Analog mode :Selected D11
Analog range : 0..20mA
Output on error : 0mA
Output if < 0 : linear
Output if > Max : 20mA
Weight at 0/4mA : 0 kg
Weight at 20mA : 1000 kg