Start physical disk blink, Start physical disk channel blink – Dell PowerVault MD3260i User Manual
Page 352
NOTE: This operation ends the iSCSI connections for the portal and brings down the portal temporarily.
Start Physical Disk Blink
Description
This command blinks a physical disk by turning on an indicator light on the physical disk. Run the stop physicalDisk blink
command to turn off the indicator light on the physical disk.
Syntax
start physicalDisk [enclosureID,slotID] blink
Parameters
Parameter
Description
physicalDisk
The location of the physical disk that you want to find. For
high-capacity expansion enclosures, specify the
enclosure ID value and the slot ID value of the physical
disk that you want to revive. Enclosure ID values are 0 to
99. Slot ID values are 0 to 31. Enclose the enclosure ID
value and the slot ID value in square brackets ([ ]).
Start Physical Disk Channel Blink
Description
This command identifies the expansion enclosures that are connected to a specific physical disk port by turning on the
indicator lights for the expansion enclosure that is connected to the physical disk port. Use the stop
physicalDiskChannel blink command to turn off the indicator lights on the expansion enclosure.
Syntax
start physicalDiskChannel [(1 | 2)] blink
Parameters
Parameter
Description
physicalDiskChannel
The identifier number of the physical disk channel that you
want to locate. Valid values for the identifier number are 1
or 2. Enclose the identifier number in square brackets ([ ]).
352